Goodman Furnace 2 flashes: What It Means & How to Fix It
Compiled & reviewed by Nikolai Tsyrenov · Updated 2026-06-25 · confidence: high
What does Goodman furnace 2 flashes mean?
Pressure-switch circuit is stuck closed at the start of the cycle when it should be open / draft inducer fault. Most often caused by Pressure-switch contacts sticking closed.
What Goodman furnace 2 flashes means
Pressure-switch circuit is stuck closed at the start of the cycle when it should be open / draft inducer fault.
Common causes
Pressure-switch contacts sticking closed
A short in the pressure-switch circuit wiring
Draft inducer not operating as expected at startup
A failed pressure switch or control board
Homeowner-safe steps to try
This is an internal combustion-side fault — there is no safe homeowner adjustment
Cycle power at the furnace switch once to see if it clears
Replace a dirty filter and keep vents clear as general good practice
Do NOT open the furnace to inspect or jumper the pressure switch
When to call a licensed HVAC technician
If the basic checks below don't clear the code, the fault recurs, or anything involves the gas valve, burners, flame sensor or wiring, stop and book a licensed HVAC technician. Repairs to the combustion or gas system are not DIY.
⚠️ Safety first. Gas furnaces burn fuel and produce combustion gases. If you ever smell gas (a rotten-egg or sulfur odor), hear hissing, or your carbon-monoxide alarm sounds, do not touch light switches, thermostats, or the furnace — leave the home immediately and call your gas utility's emergency line or 911 from outside. Homeowners should limit themselves to simple, safe steps: setting the thermostat, checking and replacing the air filter, confirming the furnace switch and breaker are on, keeping supply registers and return grilles open, and clearing snow, ice, or debris from outdoor vent and intake terminations. Never bypass, jumper, or reset safety switches (limit, flame-rollout, or pressure switches), never open the gas valve or burner compartment, and never attempt combustion, electrical, or control-board repairs yourself. Error codes point toward a problem but are not a substitute for proper diagnosis — when in doubt, turn the system off and call a licensed HVAC technician. Keep working carbon-monoxide detectors on every level of your home.
When to call a pro: Call a licensed HVAC technician — a stuck-closed pressure switch or shorted circuit requires professional diagnosis.
Goodman furnace 2 flashes FAQ
What does Goodman furnace 2 flashes mean?
Pressure-switch circuit is stuck closed at the start of the cycle when it should be open / draft inducer fault.
What causes Goodman furnace 2 flashes?
Common causes: Pressure-switch contacts sticking closed; A short in the pressure-switch circuit wiring; Draft inducer not operating as expected at startup; A failed pressure switch or control board.
Can I fix Goodman furnace 2 flashes myself?
You can safely try: This is an internal combustion-side fault — there is no safe homeowner adjustment; Cycle power at the furnace switch once to see if it clears; Replace a dirty filter and keep vents clear as general good practice; Do NOT open the furnace to inspect or jumper the pressure switch. Call a licensed HVAC technician — a stuck-closed pressure switch or shorted circuit requires professional diagnosis.
Sources: hvacdirect.com · inspectapedia.com. General information for homeowners, not professional advice — confirm against your furnace's manual and a licensed technician.